Depth

A range of pressure sensors designed for submersible depth sensing applications.

  1. DL/N/Ex

    DL/N/Ex

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -40…85 °C
    • Process temp: -5…80 °C
    • Interface: RS232
    • Aluminium, Stainless steel

    DL/N/Ex

    Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values

  2. DL/N 70

    DL/N 70

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Temp range: -5…50 °C
    • Operating temp: -5…50 °C
    • Process temp: -5…50 °C
    • Interface: RS485

    DL/N 70

    Stainless steel

    Feature: Battery operation, Measurement interval 0.5s…24h, 500'000 Measurement values

  3. GSM

    GSM

    • Operating temp: -20…55 °C
    • Data transfer: GSM
    • Freq 900, 1800/1900 MHz
    • Aluminium (Housing)
    • Battery operation,
    • Readout time: 36s/1000

    GSM

  4. ATM.1ST/N

    ATM.1ST/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    •  V  or mA output
    • Stainless steel, Titanium

    ATM.1ST/N

  5. ATM.1ST/N/Ex

    ATM.1ST/N/Ex

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • mA output 
    • Stainless steel, Titanium

    ATM.1ST/N/Ex

  6. ATM.ECO/N

    ATM.ECO/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.25 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • V or mA output
    • Stainless steel, Titanium

    ATM.ECO/N

  7. ATM.ECO/N/Ex

    ATM.ECO/N/Ex

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.25 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • mA output
    • Stainless steel, Titanium

    ATM.ECO/N/Ex

  8. ATM/N

    ATM/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • V or mA output
    • Stainless steel, Titanium

    ATM/N

    Feature: Optional surge (lightning) protection

  9. ATM/N/Ex

    ATM/N/Ex

    • 1…250 mH2O
    • Accuracy: 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • Output signal: 4…20 mA
    • Stainless steel, Titanium

    ATM/N/Ex

    Feature: Optional surge (lightning) protection

  10. ATM/N/T

    ATM/N/T

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Temp range: -5…80 °C
    • Operating temp: -5…80 °C
    • Process temp : -5…80 °C
    • 2 Output signals (p & T) 

    ATM/N/T

    Stainless steel, Titanium

  11. ATM/N 19

    ATM/N 19

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • V or mA output
    • 19 mm diameter
  12. ATM/K/N

    ATM/K/N

    • 1…200 mH2O
    • Accuracy: ≤ ± 0.25 % FS
    • Operating temp: -5…50 °C
    • Process temp: -5…50 °C
    • mA output
    • Stainless steel

    ATM/K/N

    Feature: Optional surge (lightning) protection

  13. ATM/NC

    ATM/NC

    • 1…250 mH2O
    • Operating temp: -5…50 °C
    • Process temp: -5…80 °C
    • V or mA output
    • PVDF
    • Optional surge protection
  14. ATM/Nc/Ex

    ATM/Nc/Ex

    • 1…250 mH2O
    • Operating temp: -5…50 °C
    • Process temp: -5…80 °C
    • mA output
    • Materials: PVDF
    • Optional surge protection

    ATM/Nc/Ex

  15. DTM/N

    DTM/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • Interface: RS232, RS485
    • Materials: Stainless steel
  16. PTM/N

    PTM/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • mA output
  17. PTM/N/Ex

    PTM/N/Ex

    • 1…250 mH2O
    • Accuracy: 0.10 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • mA output
    • Stainless steel, Titanium

    PTM/N/Ex

    Feature: Recalibration with software possible

  18. PTM/N/RS485

    PTM/N/RS485

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Temp range: -25…85 °C
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • Stainless steel, Titanium

    PTM/N/RS485

    2 Output signals (p & T): 4…20 mA
    Interface: RS485 (Modbus RTU)
    Feature: Recalibration with software possible, optional surge (lightning) protection

  19. PTM/N/SDI-12

    PTM/N/SDI-12

    • 5…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Temp range: -25 85 °C
    • Operating temp: -5…50 °C
    • Process temp: -5…50 °C
    • Stainless steel, Titanium

    PTM/N/SDI-12

    Interface: SDI-12 (V1.3)

    Feature: Recalibration possible, Adjustable units

  20. MTM/N 10

    MTM/N 10

    • 10…100 mH2O
    • Accuracy: 0.25
    • Operating temp: -5…50 °C
    • Process temp: -5…50 °C
    • Output signal: mV
    • Stainless steel, Titanium

    MTM/N 10

    Feature: Level transmitter with 10 mm diameter, Versions with ATM/N or DL/N 70 possible

  21. TM/N

    TM/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.25 % FS
    • Operating temp: -5…80 °C
    • Process temp : -5…80 °C
    • mV output
    • Stainless steel, Titanium
  22. TM/N/Ex

    TM/N/Ex

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.25 % FS
    • Operating temp: -5…80 °C
    • Process temp: -5…80 °C
    • Output signal: mV
    • Stainless steel, Titanium
  23. DL/Ex

    DL/Ex

    • 100 mbar…1000 bar
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -40…85 °C
    • Process temp: -40…100 °C
    • Interface: RS232
    • ATEX approval

    DL/Ex

    Battery operation, Measurement interval 2s…24h, 130'000 Measurement values. ATEX approved for use in hazardous areas, eg landfill, fuel tanks.

  24. Precise DPX3000

    Precise DPX3000

    • Total accuracy 0.01%
    • 50-2000 bar
    • RS232 and RS485 comms
    • Resolution 1ppm
    • Submersible option

    Precise DPX3000

    The PRECISE Digital Pressure Transmitter is an ultra high accuracy digital pressure and temperature sensor designed for high pressure measurement in critical applications in harsh environments where accuracy and stability of data are key to system performance.

  25. DL

    DL

    • 100 mbar…1000 bar
    • Accuracy: ≤ ± 0.10 % FS
    • Operating temp: -40…85 °C
    • Process temp: -40…100 °C
    • Interface: RS232
    • Aluminium, Stainless steel
       

    DL

    Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values

  26. DL/N

    DL/N

    • 1…250 mH2O
    • Accuracy: ≤ ± 0.10 % FS
    • Oper temp: -40…85 °C
    • Process temp: -5…80 °C
    • Interface: RS232
    • Aluminium, Stainless steel

    DL/N

    Feature: Battery operation, Measurement interval 2s…24h, 130'000 Measurement values